Haze Meter Application:
TT-M120 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis, and other aspects.
Haze Meter Technical Advantage:
Double standard ISO&ASTM
- Able to meet the test standard requirements of different users, in accordance with ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K 7136
Easy to operate, faster and more accurate measurement
- The TT-HM120 haze meter is equipped with a large-size touch screen for easy operation. With a PD array detector, CIE V(λ)2-degree visual response enables high precision and repeatable transmittance and fog measurements’ data output device for docking with laboratory system.
With compensation port, so that the measurement data more accurate
- Meet ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, fog test, provide more accurate test results.
Easy to measure and widely applicable to samples
- Open measuring area, vertical and horizontal testing, suitable for more samples to be tested.
Dynamic measurement
- Independent light source detector and temperature sensor, constantly monitor light source and environmental change, ensure the reliability of test data.
Quality control software
- It provides powerful software for measuring and analyzing fog and light transmittance, which is suitable for quality monitoring and tabulated management of fog and light transmittance data in various industries. The management of users will be digitized at the PC end, the difference of fog and light transmittance will be compared, and the test report form will be generated to facilitate customer customization and management.
Haze Meter Technical Specification:
Product Model | TT-M120 Haze Meter |
Optical Geometry | Transmittance: 0/D (Parallel light illumination, diffuse viewing); Conform to the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K 7136 |
Characteristic | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance, haze detection. |
Integrating Sphere Size | Φ154mm |
Light Source | 400nm to 700nm, combined LED light |
Spectrophotometric Mode | / |
Sensor | The PD array detector satisfies CIE V(λ)2-degree visual response |
Wavelength Range | / |
Wavelength Interval | / |
Semi band Width | / |
Measurement range | 0~100% |
Measuring Aperture | Φ20mm/Φ15mm/Φ8mm/Φ4mm (Select a single aperture) |
Sample Size | Thickness <170mm |
Color Space | / |
Color Difference Formula | / |
Other Colorimetric Index | Haze (ASTM D1003/1044, ISO13468), Transmittance T(ISO), Transmittance T(ASTM) |
Observer Angle | 2° |
Illuminant | D65, A, C |
Displayed Data | PASS/FAIL Result |
Measuring Time | About1.5s |
Resolution | 0.01unit |
Repeatability | Φ20mm, within 0.05 (After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) |
Inter-instrument Error | Φ20mm, with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
Dimension | L*W*H=290X211X511mm |
Weight | About7.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Print serial port |
Data Storage | Standard 1000 pcs, sample 20000 pcs |