The high reliability and practicability of TESTRON TT-HP9200 liquid chromatography system ensures the long-term stable we operation of the system and can be competent of any quality control and routine analysis. The computerized counter control workstation makes the experiment process easier. Meanwhile, this workstation provides powerful support for daily analysis works in various fields such as medicine, environmental protection, university scientific research, chemical industry, and food industry.
Application of TT-HP9200 Ultra High-Performance Liquid Chromatograph:
- Pharmaceuticals: for drug analysis, impurity profiling, and quality control of pharmaceutical products.
- Food and beverage: for testing food additives, pesticides, contaminants, and nutritional components.
- Environmental analysis: for monitoring pollutants, analyzing water quality, and detecting environmental contaminants.
- Forensic science: for analyzing drugs, toxins, poisons, and identifying unknown substances in forensic investigations.
- Chemical analysis: for determining the purity of chemicals, analyzing organic compounds, and studying reaction kinetics.
- Biotechnology: for analyzing biomolecules, such as proteins, nucleic acids, and peptides in research and biopharmaceutical analysis.
- Clinical diagnostics: for analyzing biomarkers, drugs, and metabolites in biological samples for medical diagnostics and research.
- Petrochemical industry: for analyzing hydrocarbons, oils, and petrochemical products for quality control and process monitoring.
- Agriculture: for analyzing pesticides, herbicides, and agricultural products to ensure safety and compliance.
- Cosmetics and personal care: for quality control, formulation analysis, and identification of ingredients in cosmetic products.
Features of TT-HP9200 Ultra High-Performance Liquid Chromatograph:
1. High Pressure Pump
- The solvent management system integrates the solvent and the tray, so that it easily expands the binary gradient system from 2 mobile phases to 4 mobile phases.
- The new solvent management system easily solves the daily tedious problems of mobile phase replacement and system cleaning and maintenance when using binary high-pressure gradient system and reduce the burden of laboratory personnel.
- With the inherent advantages of the binary high-pressure gradient, the analysis requirements of sample diversification can be easily fulfilled.
- Through the time program setting of the chromatography workstation software, it is easy to realize any combination and switch of the four mobile phases, which is convenient to change the mobile phase and flush the system after the detection of different samples.
- This could provide convenient and excellent experience for users.
2. Autosampler
- Different injection modes and precise metering pump design ensure excellent injection accuracy and long-term stability of data-analysis.
- Maintenance-free mechanical structure provides longer lifetime.
- The sample injection range is from 0.1 to 1000 μL, which ensures the high precision sampling of both large and small volume samples (the standard configuration is 0.1~100 μL).
- The short sampling cycle and the high repetitive sampling efficiency lead to quick and efficient repetitive sampling, so as to save time.
- The inner wall of the sample needle can be cleaned online inside the autosampler, that is the sample needle flushing mouth can wash the outer surface of the sample needle to ensure very low cross contamination.
- Optional sample chamber refrigeration provides cooling and heating in the range of 4-40°C for biological and medical samples.
- The independent control software can match the liquid chromatography system of many manufacturers on the market.
3. High Pressure Pump
- Advanced electronic pulse compensation is adopted to reduce the dead volume of the system and ensure the repeatability of the measurement results.
- The one-way valve, seal ring, and plunger rod are imported parts to ensure the durability of the pump.
- The multi-point flow correction curve ensures the flow accuracy within the full flow range.
- The independent pump head is easier to install and disassemble.
- The floating plunger design ensures a higher lifetime of the seal ring.
- Open-source computer communication protocol is easily controlled by third-party software.
4. UV-Vis Detector
- The dual-wavelength detector can detect two different wavelengths at the same time, which meet detection requirements of different wavelength detection items in the same sample simultaneously.
- The detector adopts imported grating with high precision and imported light source with long lifetime and short stability time.
- Wavelength positioning uses advanced high-precision stepper motor (imported from the United States) which directly control the wavelength to achieve great accuracy and reproducibility.
- In a high precision data acquisition chip, the acquisition terminal directly converts analog signal into digital signal, which avoids interference in the transmission process.
- The open communication protocol of detector is accessible for third-party software. At the same time, the optional analog acquisition circuit is compatible with other domestic chromatography software.
5. Column Oven
- The column temperature control system adopts an internationally advanced processing chip to ensure high precision and high stability.
- Independent double column design is suitable for various specifications of chromatographic columns.
- The high sensitivity sensor achieves the high accuracy of system temperature control.
- Overtemperature protection function makes the column oven safe and reliable.
- Automatic switch between the double columns (optional).
6.Chromatography Workstation
- Workstation software can fully control all unit components (except some special detectors).
- Adopts database structure, which has one-key data backup and restore function, to ensure data security.
- Adopts modular design which has simple and clear operation.
- The software displays the device status information in real time and provides the function of online modification.
- A variety of filtering methods are added to satisfy the acquisition and analysis of different SNR data.
- Integrated meets regulatory requirements, audit trails, access management and electronic signatures.
7. Fraction Collector
- The compact structure is truly suitable for the preparation of complex components and can cooperate with the analysis liquid phase to prepare high purity substances precisely.
- Using rotary manipulator design to minimize space occupation.
- A variety of tube volume settings meet the needs of different collection volumes.
- Accurate piping design reduces the dead volume and collection error caused by diffusion.
- High precision bottle cutting technology and independent waste liquid channels make the bottle cutting process without drip leakage and pollution.
- Collection containers can be identified automatically, which prevents misplacing different types of collection containers.
- Manual/Automatic collection modes make it easy to operate.
- Different collection containers are compatible. The maximum allowed collection containers: 120 pcs 13~15mm tubes.
- Multiple collection modes, such as time, threshold, slope etc., meet the requirements of different collection conditions.
Favorable Expansibility of TT-HP9200 Ultra High-Performance Liquid Chromatograph:
Autosampler, UV-Vis detector, differential detector, evaporative light- scattering detector, fluorescence detector, and fraction collector are optional to meet the requirements of different samples.
Technical Specification of TT-HP9200 Ultra High-Performance Liquid Chromatograph:
Model | TT-HP9200 | |
Working Condition | Power Supply | single phase 220V ±10% 50/60Hz |
Environmental temperature | 15-35℃ | |
Environmental humidity | <85% | |
Four element infusion pump | Series connect double plunger reciprocating pump, double ball one-way valve, dual efficiency ensures high-pressure sealing | |
Independent four channel design, any 2/3/4 channel online mixing, can achieve ≥ 4 types of solvent mixing | ||
Standard 4-channel online degassing machine can be upgraded to 1-channel online degassing machine, which can also achieve online degassing of needle washing solution, reduce bubbles, and increase injection accuracy | ||
Flow Precision | ≤0.06% RSD (@1mL/min,water) (ASTM) | |
Flow Rate | 0.001 mL/min – 10.000 mL/min (increment 0.001mL/min) | |
Flow accuracy | ±0.5% (@1mL/min,water) | |
Pressure range | 0-10500 psi(72Mpa) | |
Gradient accuracy | ±0.5% | |
Gradient repeatability | ≤0.2% SD | |
Pressure pulsation | ≤1% (@1mL/min, water, back pressure >10Mpa) | |
Variable wavelength UV visible detector | Advanced optical path design, powerful DSP drive, dual lights can be automatically controlled and switched, avoiding manual switching delays and errors. The insulation device ensures sufficient and stable energy throughout the entire wavelength range, thereby achieving lower detection limits and detection ranges. The side deuterium lamp positioning system can facilitate and quickly replace deuterium lamps. | |
Light Source | Deuterium Lamp, Tungsten Lamp,light source number≥2 | |
Wavelength Range | 190-900nm | |
Wavelength calibration | Automatic correction of deuterium lamp and built-in holmium oxide filter | |
Wavelength precision | ±0.1 nm | |
Wavelength accuracy | ±1 nm | |
Noise | ±5.0×10-6AU (JJG) / ±3.5×10-6AU (ASTM) | |
Baseline drift | 1×10-4AU/Hr | |
Linear range | >5×104 (JJG) / >2.5AU (ASTM) | |
Spectral Bandwidth | 8 nm | |
Maximum Sample Rate | 100Hz | |
Programmable wavelength time program | wavelength, peak width, deuterium lamp on/off, automatic signal zeroing, sampling frequency, sampling time, etc | |
Column oven | Large capacity space design, accommodating at least four 300mm long chromatography columns. | |
Adopting intelligent temperature control design and forced air circulation system, it can quickly reach the set temperature and ensure temperature stability. Standard temperature and time program, which can achieve stage constant temperature and interval heating and cooling | ||
Temperature control range | ambient +5 ℃ – 85 ℃ | |
Temperature accuracy | ±1.0 ℃ | |
Temperature Stability | ±0.1 ℃ | |
Injection system | Injection mode | Full loop injection, partial loop fill injection, μL pickup injection |
Injection volume | ≥108 positions (1.5mL), (2*96 positions plate injection optional) | |
Quantitative ring volume | standard 100 μL, (20 μL, 50 μL, 200 μL, 000 μL optional) | |
Sample accuracy | ≤0.3%RSD | |
Samples of residual | <0.0025% | |
Refrigeration function optional |