Oxygen Permeability Analyzer Application
- Plastic film, composite film, aluminum foil, aluminized film, etc.
- Sheet, panel, rubber, ceramics, etc.
- Packaging containers, such as glass, bottles, cans, boxes, etc.
- Expanding application: solar panel, LCD film, medical patch, etc.
Widely used in quality inspection organizations, drug control institutions, research institutes, packaging, thin-film, food companies, pharmaceutical enterprises, personal care industry, and electronics industry, and so on.
Oxygen Permeability Analyzer Standard
ASTM D3985, ASTM F2622, ASTM F1927,ASTM F1307, ISO 15105-2, DIN 53380-3,JIS K-7126-B, GB/T19789-2005, YBB00082003-2015,
Oxygen Permeability Analyzer Specification
Item | Technical parameters |
---|---|
Test range | 0.02~16500 cm3/m2•24h(Film)With mask can be 260000 cm3/m2•24h |
Test Accuracy | 0.001 cm3/m2•24h |
Temperature range | 15~45℃ |
Temperature accuracy | ±0.1℃ |
Humidity range | 30~90%RH,100%RH |
Humidity accuracy | ±1%RH |
Test area | 50.24 cm2(minimum 0.785 cm2 optional) |
Sample size | Φ100 mm |
Sample thickness | ≤3mm |
Number of samples | 1 piece |
Carrier Gas pressure | ≥0.1MPa |
Carrier gas port | Φ3mm gas pipe |
Instrument size | 600×400×330mm |
Weight | 80kg |
Power | 750W |
Power supply | AC 220V,50Hz |
Oxygen Permeability Analyzer Features
Accurate and reliable data
With The State Certificate for Gradation of the Certified Reference Materials, and license for Manufacturing Measuring Instruments of the state Reference Material (GBW(E)130497/8)of Oxygen permeability analyzer approved and issued by General Administration of Quality Supervision, Inspection and Quarantine of the P.R.C. Adopting state reference materials to calibrate and verify the instruments, ensure the accuracy, universality, and authority of the test data.
Simple operation
- LCD and windows instrument interface show testing data and working status in real-time; mouse operation is simple and convenient.
- Professional software with a simple interface, easy to use, and convenient to set test process.
- Fully-auto operation, judge, and stop automatically.
- Real-time curves display transmission, oxygen concentration, temperature and humidity, curves can be easily zoomed and moved. The curves with concealing function, support query function for background data.
- Professional test report; can be exported as PDF.
Advanced technology
- Temperature control: International advanced electromagnetic technology, program-controlled, auto heating and cooling; and no need for external accessories. Precision: 0.1℃.
- Humidity control: Dual gas flow method (dry gas and humid gas), with a broad range, high precision (1%RH), and stable flow.
- Carrying cutting-edge ARM controlling systems can run independently without a computer.
High efficiency
- Measurement precise up to 0.001 cm3/(m2•24h), can test high barrier materials, such as aluminum foil.
- By adding package-testing accessories, can test oxygen transmission of various containers such as bag, bottle, can, and bowl.
- By adding an adaptive accessory, can expand the upper limit of test range to 260000 cm3/m2•24h.
Calibration & Certification
- The instrument supports two methods of reference materials and standard gas to certificate and calibrate; Operation is simple, the user only needs to use certified reference materials for normal testing, and then input the test result into the instrument interface to complete calibration.
Reliable and easy-maintenance instrument
- The imported oxygen sensor, with high precision and good performance, can work for a long time.
- Sensor over-range auto protection.
- Function modularization, easy to maintain.
Oxygen Permeability Analyzer Configuration List
Spare parts | |||
---|---|---|---|
NO. | Name | Remark | Quantity |
1 | Power cable | 3*0.75 10A 1.8M | 1 PC |
2 | Communication cable | RS232nine-pin data cable | 1 PC |
3 | Sample cutter | Sample diameter 100mm(Tly-0.01) | 1 PC |
4 | Sealing grease | HFV-GS(HFV-GS 70g) | 1 PC |
5 | Metal gas pipe | 1/8“(0D)*2.1mm.SS316 | 5 M |
6 | Ferrule connector Ferrule connector | 1 piece of MC-01-01NPT 1/8 1 piece of MC-01-02 NPT 1/4 | 4 PCS |
7 | Reference material | 125μm | 1 set |
8 | Special spanner | M10 & M3 | 2 PCS |
9 | Injection syringe | Medical disposable 1 ML | 1 PC |
10 | Sealing circle | φ12 | 4 PCS |
11 | Straddle wrench | 12mm | 1 set |
12 | Cross screwdriver | 6-10mm | 1 PC |
13 | Mouse | RAPOO M10 | 1 PC |
14 | Wooden box | 1 PC |
Optional parts | ||||
---|---|---|---|---|
NO. | Name | Unit | Quantity | Remark |
1 | Computer | Optional | ||
2 | Metrology Certificates | Optional |
User provides | |
---|---|
1 | Laboratory requirements: ordinary laboratory with air conditioner, temperature stale at 23°±2 |
2 | Experiment table requirements: table size length 200cm*width 80cm*height 80cm |
3 | Power supply:220V 1 piece of three-hole switch socket with three-position,10A |
4 | Computer requirements: standard configuration (Windows7, with nine-pin serial port) |
5 | 1 bottle of oxygen, purity must above 99.999%,with a pressure reducing valve, output range is 0-0.4Mpa |
6 | 1 bottle of nitrogen, purity must 99.999%,with a pressure reducing valve, output range is 0-0.4Mpa |